Cross-linking Steam Room

Product Category

Related Cases

Cross-linking cable

Cross-linked cable is the abbreviation of cross-linked polyethylene insulated cable. Cross-linked cable is suitable for power transmission and distribution lines with power frequency AC voltage of 500KV and below. At present, most high-voltage cables use cross-linked polyethylene insulation.
Cross-linked polyethylene is a cross-linked polyethylene that uses chemical or physical methods to transform linear molecular structure polyethylene into a three-dimensional network structure, thereby greatly improving the thermo-mechanical properties of polyethylene and maintaining excellent Electrical performance.

Cross-linking steam room

The design of the steam cross-linking room follows the principles of high operational safety, good insulation performance, homogeneous temperature and humidity, good air-tightness, automatic and accurate electronic control. Therefore, steam should be allowed to penetrate into each layer of the insulated single wire under constant temperature and constant pressure. In the gap between, the uniform cross-linking effect has been achieved:

 

  1. Convenient operation and high safety

Since the steam room adopts the omnidirectional pipeline steam heating scheme, the steam shows the characteristics of strong permeability and evenly heating. The steam cross-linking method can make the insulation cross-linking more balanced. At the same time, because the steam room is easy to operate, it can effectively avoid the damage on the cable due to crane lifting, reduce the hidden quality hazards of oxidation of cable conductors caused by water ingress.

 

  1. High working efficiency and short cross-linking cycle

Compared with water pool method, each pool can only store one wire core at a time, and each steam room can hold at least 4 wire cores at a time. The cross-linking time of each batch of wire cores can be shortened by about 20%. So, the daily amount of cross-linked coils has increased by 5 times compared with the past, speeding up the circulation of semi-finished products and greatly improving production efficiency.

 

  1. Automatic

 The new steam room adopts solenoid valve thermostatic control and over pressure protection device. After setting the temperature and time, it can realize automatic temperature control without personnel on duty and effectively save labor cost.

Steam room characteristics

Insulation

PU, 10cm

Surface

Stainless steel, 201

Control

Time, temperature, pressure

Steam source

Electrical heating; commercial steam

Loading/unloading

Manual rolling in/out; folk-lift

Shipment status

Ready assembled; site assembly

Ambition temperature

< -30C°

Size

On request

Power installation

48kw for 2.5m*4m workshop application